チラーユニット
62/160

60Hz加熱能力表■特性/連続制御タイプ[標準仕様・ポンプ搭載仕様](空冷ヒートポンプ式)1510650-5-10-1535404550556035404550556035404550556035404550556035404550556035404550556035404550556035404550556029.531.935.640.647.050.729.131.535.039.845.949.128.731.134.639.244.947.828.631.034.539.044.747.528.130.633.938.343.546.024.927.130.133.738.143.224.526.729.633.037.041.724.126.329.132.336.040.222.722.622.522.421.418.522.322.121.921.720.617.720.920.620.320.018.916.220.420.119.819.518.415.718.117.717.216.815.713.314.213.713.212.711.89.812.111.510.910.49.4―10.09.3――――77.276.676.075.369.353.274.773.572.371.164.749.166.464.763.061.355.341.863.661.960.258.652.739.551.149.146.644.739.529.232.930.828.826.923.516.824.622.420.318.715.5―17.415.3――――16.216.116.116.015.313.215.915.815.715.514.712.714.914.714.514.313.511.614.614.414.113.913.111.212.912.612.312.011.29.510.19.89.49.1――――――――――――――41.841.341.340.937.728.840.440.039.538.635.026.935.935.034.233.330.022.834.633.832.531.728.421.427.626.525.324.221.415.917.716.815.514.7――――――――――――――周囲空気湿球温度温水出口温度加熱能力消費電力温水流量水圧損失温水出入口温度差Δt=5℃Δt=7℃(m3/h)(m3/h)(kW)(kPa)(kPa)(℃)(℃)(kW)131.9131.4130.8130.3124.3107.7129.8128.6127.4126.2119.8103.2121.5119.7118.0116.3109.894.0118.7116.9115.0113.2106.791.2105.2102.7100.397.891.377.482.579.776.974.168.457.170.367.063.660.354.544.658.154.250.346.440.732.1RHF1180AZ(P)11510650-5-10-1535404550556035404550556035404550556035404550556035404550556035404550556035404550556035404550556039.642.847.754.563.167.939.042.247.053.461.565.838.541.746.452.660.264.238.441.646.352.459.963.737.741.045.551.358.361.633.436.440.345.251.157.932.835.839.744.349.755.932.335.339.043.348.353.828.828.728.628.527.223.528.428.127.927.626.222.626.626.225.825.424.020.626.025.625.224.723.319.923.022.521.921.420.016.918.017.416.816.214.912.515.414.613.913.211.9―12.711.911.0―――75.475.074.574.068.052.173.572.171.269.863.548.565.363.561.860.054.141.062.660.959.257.151.338.550.148.145.844.038.928.632.130.228.326.522.816.524.221.920.118.315.1―17.015.113.1―――20.620.520.420.319.416.820.320.119.919.718.716.119.018.718.418.217.114.718.518.318.017.716.714.216.416.015.715.314.312.112.912.412.011.6――11.0―――――――――――41.040.640.339.936.828.339.939.238.537.834.426.235.434.433.432.729.222.233.733.132.131.128.020.827.125.925.023.921.115.617.516.315.314.4――13.1―――――――――――周囲空気湿球温度温水出口温度加熱能力消費電力温水流量水圧損失温水出入口温度差Δt=5℃Δt=7℃(m3/h)(m3/h)(kW)(kPa)(kPa)(℃)(℃)(kW)167.7167.0166.3165.6158.1136.9165.0163.5161.9160.4152.3131.1154.4152.2150.0147.8139.5119.5150.9148.6146.2143.9135.6116.0133.7130.6127.4124.3116.198.3104.9101.397.894.286.972.689.485.180.976.669.356.773.968.963.959.051.740.8RHF1500AZ(P)11510650-5-10-1535404550556035404550556035404550556035404550556035404550556035404550556035404550556035404550556051.155.161.570.281.387.650.354.460.668.979.284.949.653.859.867.877.682.749.453.659.667.577.282.248.652.858.766.175.279.443.046.952.058.365.874.742.346.251.157.064.072.041.645.550.355.862.269.434.634.534.334.232.628.334.133.733.433.131.427.131.931.431.030.528.824.731.230.730.229.728.023.927.627.026.325.724.020.321.620.920.219.417.915.018.417.616.715.814.3―15.214.213.212.2――79.579.178.377.971.455.177.575.874.673.466.751.068.666.765.163.256.943.065.964.062.160.254.140.552.750.648.346.340.830.133.731.729.827.723.917.325.223.221.119.115.9―17.815.713.711.9――24.724.624.524.423.320.224.324.123.923.622.419.322.822.422.121.820.617.622.321.921.621.220.017.119.719.318.818.317.114.515.514.914.413.9――13.2―――――――――――43.042.742.442.138.729.841.841.240.539.636.027.537.236.035.134.330.923.235.734.633.732.629.322.028.527.526.224.922.016.318.417.116.115.1――13.7―――――――――――周囲空気湿球温度温水出口温度加熱能力消費電力温水流量水圧損失温水出入口温度差Δt=5℃Δt=7℃(m3/h)(m3/h)(kW)(kPa)(kPa)(℃)(℃)(kW)201.2200.4199.6198.8189.7164.3198.0196.2194.3192.5182.7157.4185.3182.6180.0177.4167.5143.4181.1178.3175.5172.7162.8139.2160.5156.7152.9149.2139.3118.0125.8121.6117.3113.1104.387.1107.3102.197.091.983.268.188.782.776.770.762.149.0RHF1800AZ(P)1温水流量水圧損失温水流量水圧損失温水流量水圧損失    内は標準仕様値を示します。本表は、蒸発器に着霜していない時を示します。着霜時は、着霜量に応じて能力が80%程度まで低下しますので、考慮が必要です。また、降雪により、空気側熱交換器表面に雪が付着する場合には、さらに能力が低下しますので、ご注意ください。[ ― ]は冷水流量がΔt=5℃あるいはΔt=7℃では最小流量を下まわる場合を示します。水圧損失は標準仕様機の場合の数値です。(ポンプ搭載仕様機では水圧損失は発生しません。)(1)(2)(3)(4)注注注注空冷ヒートポンプ式/空冷式冷専スクリュー(モジュールタイプ)61

元のページ  ../index.html#62

このブックを見る