スクロールクーリングシステム
36/262

KU-N2HTV-FKU-N3HTV-FKU-N4HTV-FKU-N5HTV-FKU-N6HTV-FKU-N7HTV-FKU-N8HTV-FKU-N10HTV-FKU-N12HTV-FKU-N15HTV-FKU-N20HTV-FKU-N26HTV-FKU-N30HTV-F呼称出力(kW)セット型式インバーター周波数庫内温度(℃)1510550/60Hz(単位 : kW)1.52.23.03.74.55.26.07.07.88.815.116.517.6(注)外気(凝縮器吸込空気)温度32℃・冷媒配管長(水平片道)5mで無着霜の場合の値を示します。――――定格最大定格最大定格最大――――――5.30/5.607.50/7.5010.0/10.011.8/11.813.2/14.015.6/15.815.0/15.017.4/17.417.0/17.018.4/18.422.4/22.426.5/26.528.0/28.045.0/47.553.0/56.056.0/60.05.82/6.208.10/8.1011.0/11.012.7/12.714.8/15.516.7/16.716.9/16.918.2/18.218.7/18.719.3/19.325.2/25.228.5/28.530.0/30.050.0/52.657.3/60.860.9/64.96.33/6.618.59/8.5912.1/12.113.4/13.416.2/16.817.4/17.418.4/18.418.4/18.419.5/19.519.5/19.527.6/27.630.3/30.332.0/32.054.6/58.259.3/62.463.6/67.2●高温用低 風 量 型標 準 型●中温用KU-N2MHV-FKU-N3MHV-FKU-N4MHV-FKU-N5MHV-FKU-N6MHV-FKU-N7MHV-FKU-N8MHV-FKU-N10MHV-FKU-N12MHV-FKU-N15MHV-FKU-N20MHV-FKU-N26MHV-FKU-N30MHV-FKU-N36MHV-FKU-N40MHV-F呼称出力(kW)セット型式インバーター周波数庫内温度(℃)-551001550/60Hz(単位 : kW)1.52.23.03.74.55.26.07.07.88.815.116.517.623.625.0(注)外気(凝縮器吸込空気)温度32℃・冷媒配管長(水平片道)5mで無着霜の場合の値を示します。4.27/4.455.96/5.968.1/8.19.2/9.210.3/11.112.4/12.911.5/11.514.2/14.213.5/13.515.0/15.019.0/19.020.5/20.524.7/24.735.0/39.542.0/44.544.5/47.055.0/59.559.0/62.04.75/5.006.70/6.709.0/9.010.6/10.611.8/12.514.1/14.613.2/13.216.1/16.115.0/15.017.0/17.021.2/21.223.6/23.628.0/28.040.0/45.047.5/50.050.0/53.063.0/71.067.0/71.05.30/5.607.50/7.5010.0/10.011.8/11.813.2/14.015.6/15.815.0/15.017.4/17.417.0/17.018.4/18.423.6/23.626.5/26.530.0/30.045.0/50.053.0/56.056.0/60.071.0/80.075.0/80.05.82/6.208.10/8.1011.0/11.012.7/12.714.8/15.516.7/16.716.9/16.918.2/18.218.7/18.719.3/19.325.9/25.928.5/28.531.6/31.650.0/54.557.3/60.860.9/64.977.9/85.681.1/87.66.33/6.618.59/8.5912.1/12.113.4/13.416.2/16.817.4/17.418.4/18.418.4/18.419.5/19.519.5/19.527.6/27.630.3/30.333.0/33.054.6/58.259.3/62.463.6/67.282.6/88.586.3/92.4――――定格最大定格最大定格最大――――――――●低温用KU-N2LHV-FKU-N3LHV-FKU-N4LHV-FKU-N5LHV-FKU-N6LHV-FKU-N8LHV-FKU-N10LHV-FKU-N12LHV-FKU-N15LHV-FKU-N20LHV-FKU-N26LHV-FKU-N30LHV-FKU-N36LHV-FKU-N40LHV-F呼称出力(kW)セット型式庫内温度(℃)-5-10-15-20-25-30-3550/60Hz(単位 : kW)1.52.23.03.74.56.07.07.88.815.116.517.623.625.0(注)外気(凝縮器吸込空気)温度32℃・冷媒配管長(水平片道)5mで無着霜の場合の値を示します。1.83/1.832.42/2.423.55/3.553.75/3.754.38/4.385.68/5.687.9/7.98.6/8.610.1/10.115.9/16.517.5/18.018.6/18.923.0/26.025.5/27.71.51/1.511.98/1.982.96/2.963.05/3.053.72/3.725.07/5.076.6/6.67.4/7.48.3/8.313.8/13.915.1/14.915.9/15.819.5/22.121.4/23.42.16/2.162.89/2.894.15/4.154.50/4.505.16/5.166.50/6.509.2/9.210.1/10.112.0/12.018.5/19.320.3/21.421.8/22.527.0/30.530.0/32.62.50/2.503.35/3.354.75/4.755.30/5.306.00/6.007.50/7.5010.6/10.611.8/11.814.0/14.021.2/22.423.6/25.025.0/26.531.5/35.533.5/37.52.87/2.873.82/3.825.36/5.366.18/6.186.95/6.958.75/8.7512.3/12.313.7/13.716.2/16.224.2/25.727.5/29.629.7/31.137.0/41.040.0/43.13.24/3.244.29/4.295.97/5.977.10/7.107.95/7.9510.2/10.214.0/14.015.7/15.718.5/18.527.6/29.432.2/34.234.0/35.943.0/46.945.5/48.73.63/3.634.75/4.756.55/6.558.11/8.119.09/9.0911.8/11.815.8/15.817.8/17.820.9/20.930.8/33.037.0/39.138.7/40.949.4/52.651.3/54.4コントローラー設備設計・据付上のご注意R404Aクーリングシステム セット型インバータースクロールR404Aクーリングシステム セット型スクロールクーリングシステム セット型インバータースクロールR410Aクーリングシステムセレクト型R410AR404A冷凍冷蔵ユニットクーリングシステム セット型インバーターR448A35冷却能力一覧表 [インバータースクロールクーリングシステム]R410A

元のページ  ../index.html#36

このブックを見る