周囲空気乾球温度周囲空気乾球温度周囲空気乾球温度50Hz冷却能力表■特性/連続制御タイプ[標準仕様・ポンプ搭載仕様](空冷ヒートポンプ式)1520253035405791215205791215205791215202530579121520253057912152025305791215202530冷水出口温度冷却能力消費電力冷水流量水圧損失冷水流量水圧損失冷水出入口温度差Δt=5℃Δt=7℃(m3/h)(m3/h)(kW)(kPa)(kPa)(℃)(℃)(kW)RHF1180AZ(P)11520253035405791215205791215205791215202530579121520253057912152025305791215202530冷水出口温度冷却能力消費電力冷水流量水圧損失冷水流量水圧損失冷水出入口温度差Δt=5℃Δt=7℃(m3/h)(m3/h)(kW)(kPa)(kPa)(℃)(℃)(kW)RHF1500AZ(P)11520253035405791215205791215205791215202530579121520253057912152025305791215202530冷水出口温度冷却能力消費電力冷水流量水圧損失冷水流量水圧損失冷水出入口温度差Δt=5℃Δt=7℃(m3/h)(m3/h)(kW)(kPa)(kPa)(℃)(℃)(kW)RHF1800AZ(P)120.020.521.021.822.523.222.423.023.524.325.125.824.725.325.826.627.428.228.928.926.927.428.028.829.730.431.231.228.929.430.030.931.832.633.333.331.532.132.833.734.635.436.236.219.821.222.424.326.127.919.320.521.823.725.627.318.720.021.223.024.926.728.428.418.119.320.522.424.326.027.727.717.018.219.321.222.924.626.126.115.817.018.120.021.723.224.824.860.268.275.387.499.5112.357.564.171.783.596.0107.954.361.368.279.191.3103.7116.0116.051.157.564.175.387.498.8110.8110.845.651.757.568.278.489.399.599.540.045.651.161.371.180.390.790.714.115.116.017.318.719.913.814.615.617.018.319.513.414.315.116.517.819.020.320.312.913.814.616.017.318.619.819.812.213.013.815.116.317.618.718.711.312.212.914.315.516.617.717.732.536.840.947.154.360.831.234.639.045.652.258.629.633.336.843.249.655.963.063.027.631.234.640.947.153.760.260.225.028.031.236.842.348.654.354.321.725.027.633.338.643.749.149.1115.0123.0130.0141.0152.0162.0112.0119.0127.0138.0149.0159.0109.0116.0123.0134.0145.0155.0165.0165.0105.0112.0119.0130.0141.0151.0161.0161.099.0106.0112.0123.0133.0143.0152.0152.092.099.0105.0116.0126.0135.0144.0144.026.126.727.428.429.330.229.229.930.631.632.633.532.232.933.634.635.736.737.637.635.035.736.437.538.639.640.640.637.638.339.140.241.342.443.443.441.041.842.643.845.046.147.247.224.626.327.930.332.534.724.125.627.229.631.834.123.424.926.528.731.133.235.335.322.524.125.627.930.332.334.434.421.222.724.126.328.630.632.732.719.821.222.524.827.028.930.830.856.664.071.282.794.0105.954.660.968.079.390.3102.651.757.964.875.086.797.7109.2109.248.154.660.971.282.792.9104.2104.243.248.954.664.074.584.295.095.038.243.248.157.567.175.985.285.217.618.819.921.623.224.817.218.319.421.122.724.316.717.818.920.522.223.725.225.216.117.218.319.921.623.124.624.615.116.217.218.820.421.923.323.314.115.116.117.719.320.622.022.030.834.738.544.750.957.529.533.136.842.848.955.428.031.435.140.647.052.959.259.226.229.533.138.544.750.556.656.623.326.529.534.740.345.851.351.320.623.326.231.136.441.046.246.2143.0153.0162.0176.0189.0202.0140.0149.0158.0172.0185.0198.0136.0145.0154.0167.0181.0193.0205.0205.0131.0140.0149.0162.0176.0188.0200.0200.0123.0132.0140.0153.0166.0178.0190.0190.0115.0123.0131.0144.0157.0168.0179.0179.033.434.335.136.437.638.837.438.339.240.541.843.041.242.243.144.445.847.048.248.244.845.846.748.149.550.852.152.148.249.150.151.653.054.355.655.652.653.654.756.257.759.160.560.529.931.833.736.639.642.129.131.133.035.838.741.328.230.132.034.937.740.242.842.827.329.231.133.936.639.241.841.825.627.529.232.034.737.239.639.623.925.627.330.132.735.137.337.361.068.275.888.1101.7113.758.065.573.084.697.6109.854.861.769.080.893.0104.6117.2117.251.658.465.576.688.199.9112.3112.345.952.358.469.080.090.8101.7101.740.545.951.661.771.881.791.291.221.422.724.126.228.330.120.822.223.625.627.629.520.121.522.924.926.928.730.630.619.520.922.224.226.228.029.929.918.319.720.922.924.826.528.328.317.118.319.521.523.325.126.726.733.136.941.247.955.161.731.535.439.645.952.759.529.633.437.543.750.356.663.663.628.031.735.441.547.954.161.061.024.928.531.737.543.448.955.155.122.024.928.033.438.744.349.649.6174.0185.0196.0213.0230.0245.0169.0181.0192.0208.0225.0240.0164.0175.0186.0203.0219.0234.0249.0249.0159.0170.0181.0197.0213.0228.0243.0243.0149.0160.0170.0186.0202.0216.0230.0230.0139.0149.0159.0175.0190.0204.0217.0217.0    内は標準仕様値を示します。水圧損失は標準仕様機の場合の数値です。(ポンプ搭載仕様機では水圧損失は発生しません。)(1)(2)注注50/60Hz最小流量は実際に使用される冷水出口温度により異なります。( )内の値は、冷却運転の冷水出口温度が5℃未満または、20℃を超えてご使用になる場合の最小流量です。最小保有水量は、圧縮機の発停頻度および除霜時の温水温度低下を基準内に収めるために必要な最低限の水量です。水温制御を安定させるための必要水量ではありませんのでご注意ください。最小保有水量は下記条件で算出した値を記載しております。「加熱負荷:標準仕様欄加熱能力の85%相当、除霜中温水入口温度低下幅の許容値:20℃」加熱負荷・温水入口温度低下幅の許容値が変わると保有水量も変わりますのでご注意ください。注(1)注(2)注(3)乾球 -5~434~30乾球 -14.7~21 / 湿球 -15~15.535~6011(23)421.03/1.171.0以下(ポンプ搭載仕様は0.7以下)9(18)330.82/0.9113(28)501.24/1.38型式項目・単位最小流量最大流量最小保有水量許容水圧吸込空気温度冷水出口温度吸込空気温度温水出口温度℃℃℃℃m3/hm3/hm3MPa冷却加熱RHF1180AZ1RHF1180AZP1RHF1500AZ1RHF1500AZP1RHF1800AZ1RHF1800AZP1特別な改造をしないで標準のまま使用できる範囲は次のとおりです。■使用範囲および最小保有水量52

元のページ  ../index.html#53

このブックを見る